5 Commands
CommPlete Communications Server 57
settrap
Parameter: IP Address
Description: Changes the default trap IP address to the one specified in the parameter. This IP address is
where fault and status traps are sent. See se.
Security: Supervisor
Limitations: Only one default trap address may be set at a time.
Example:
[0] A:\ # settrap 199.199.199.6
Trap IP Address 199.199.199.6 stored
[1] A:\ #
setwritecommunity
Parameter: None
Description: Changes the Write community settings.
Security: Supervisor
Example:
[0] A:\ # setwritecommunity public
Write Community public stored
[1] A:\ #
sync
Parameter: None
Description: Writes oustanding events (events that normally get written every hour) to the
B:\#MMM\MR.log directory. The file will be named the current date and hour with an hour extension.
Security: Operator
Example:
[01] A:\ # sync
[02] A:\ #
t, time
Parameter: None
Description: Prompts you to change the time on the MR9600.
Security: Operator
Limitations: The time is not corrected for daylight savings time.
Example:
[0] A:\MMM # t
The current time is: 4:59pm
Enter the new time: hh:mm 17:10
[1] A:\MMM # cl
10/30/1996 5:10pm
[2] A:\MMM # t
The current time is: 5:10pm
Enter the new time: hh:mm 5:12pm
[3] A:\MMM # cl