4 AT Commands, S-Registers, and Result Codes
43
Register Unit Range Default Description
S95 decimal 015 0 The bits in this register can be set to over-
ride some of the W command options. A bit
set to a 1 in this register enables the corre-
sponding result code regardless of the W
setting.
Bit 0 CONNECT result code indicates
DCE speed instead of DTE speed.
Bit 1 Append /ARQ to CONNECT XXX
result code in error-correction mode.
Bit 2 Enable CARRIER XXXX result code.
Bit 3 Enable PROTOCOL XXXX result code.
Bit 4 Reserved.
Bit 5 Enable COMPRESSION result code.
Bit 6 Reserved.
Bit 7 Reserved.