Multitech MT5600SMI Especificaciones Pagina 69

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 68
Chapter 3 – SocketModem (MT5634SMI-34 & MT5634SMI-92)
Multi-Tech Systems, Inc. Universal Socket Hardware Guide for Developers (S000342C) 69
Timing Requirements
Timing Requirements for Parallel Write
Parameter Min Max Unit
–DS to –WR Setup (low to low) 10 - ns
A0, A1, A2 to –WR Setup (valid to low) 15 - ns
–WR Pulse Width (low to high) 40 - ns
D0–D7 to –WR Setup (valid to high) 30 - ns
–WR to –DS hold (high to high) 0 - ns
–WR to A0–A2 Hold (high to invalid) 0 - ns
–WR to D0–D7 Hold (high to invalid) 0 - ns
–WR interaccess (high to low)
Non-MIMIC Accesses
MIMIC Accesses
10
110
-
-
ns
ns
Timing Requirements for Parallel Read
Parameter Min Max Unit
–DS to –RD Setup (low to low) 10 - ns
A0, A1, A2 to –RD Setup (valid to low) 15 - ns
–RD Pulse Width (low to high) 40 - ns
–RD to –DS hold (high to high) 0 - ns
–RD to A0–A2 Hold (high to invalid) 0 - ns
–WR interaccess (high to low)
Non-MIMIC Accesses
MIMIC Accesses
10
110
-
-
ns
ns
Vista de pagina 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 137 138

Comentarios a estos manuales

Sin comentarios