Index
Multi-Tech Systems, Inc. AT Commands for the MT5634 Family of Products (S000272J) 31
Index
1
11-Bit Mode .............................................................. 15
A
Abort Timer S7 ......................................................... 26
Adaptive Answer Result Code Enable %A ............... 14
Answer A .................................................................... 8
Asynchronous Communications Mode &Q ............... 12
Asynchronous Word Length $EB ............................. 15
AT Command Control %DC ..................................... 14
AT commands
$D – DTR Dialing .................................................. 15
$EB – Asynchronous Word Length ....................... 15
$FC – Quick Connect ........................................... 15
$LB – Long Break ................................................. 15
$MB – Modem Baud Rate .................................... 16
$RP – Response Priority ...................................... 16
$SB – Serial Port Baud Rate ................................ 16
%%%ATMTSMODEM – Escape Configuration for
Remote Configuration ....................................... 23
%A – Adaptive Answer Result Code Enable ........ 14
%B – View Numbers in Blacklist ........................... 14
%C – Data Compression Control .......................... 14
%DC – AT Command Control ............................... 14
%DT – Set Command Mode Time ........................ 15
%E – Fallback and Fall Forward Control .............. 15
%H – Direct Connect Enable ................................ 15
%M – Enable Dialing Message ............................... 9
%R – Cisco Configuration .................................... 15
%S – Command Speed Response ....................... 15
&C – DCD Control ................................................ 11
&D – DTR Control ................................................. 11
&E – XON/XOFF Pacing ...................................... 11
&F – Load Factory Settings .................................. 11
&G – V.22bis Guard Tone Control ........................ 11
&K – Flow Control Selection ................................. 12
&L – Leased-Line Operation ................................. 12
&Q – Asynchronous Communications Mode ........ 12
&S – Data Set Ready (DSR) Control .................... 12
&T – V.54 Test ...................................................... 12
&V – Display Current Settings .............................. 12
&W – Store Current Configuration ........................ 12
&Z= – Storing a Dialing Command ....................... 13
+++AT – Escape Sequence .................................. 23
+DCS= – Select V.44 Data Compression ............. 18
+DR= – V.44 Data Compression Reporting .......... 18
+DS44= – V.44 Data Compression ...................... 19
+MS= – Modulation Selection ............................... 20
+PCW= – Call Waiting Enable .............................. 17
+PIG= – PCM Upstream Enable ........................... 17
+PMH= – Modem on Hold Enable ........................ 17
+PMHF – V.92 Modem Hook Flash ...................... 17
+PMHR= – Modem on Hold Initiate ...................... 17
+PMHT= – Modem on Hold Timer ........................ 18
+PQC= – Quick Connect Control .......................... 18
+VCID= – Caller ID Selection ............................... 21
+VDR= – Distinctive Ring Report ......................... 21
+VRID – Caller ID Query ...................................... 21
A – Answer ............................................................. 8
\A – Select Maximum MNP Block Size ................. 13
A/ – Repeat............................................................. 8
AT – Attention Code ............................................... 8
B – Communication Standard Setting ..................... 8
\B – Transmit Break .............................................. 13
-C – Data Calling Tone ......................................... 14
D – Dial ................................................................... 8
DS=n – Dial Stored Telephone Number ................. 9
E – Echo ................................................................. 9
F – Echo Online Data Characters ........................... 9
H – Hook Control .................................................... 9
I – Information Request .......................................... 9
\K – Break Control ................................................ 13
M – Monitor Speaker Mode .................................... 9
\N – Error Correction Mode Selection ................... 13
N – Modulation Handshake .................................. 10
O – Return Online to Data Mode .......................... 10
P – Pulse Dialing .................................................. 10
\Q – Flow Control Selection .................................. 14
Q – Result Codes Enable/Disable ........................ 10
Sr? – Read Register Value ................................... 10
Sr= – Set Register Value ...................................... 10
\T – Inactivity Timer .............................................. 14
T – Tone Dialing ................................................... 10
\V – Protocol Result Code .................................... 14
V – Result Code Form .......................................... 10
W – Result Code Options ..................................... 10
X – Result Code Selection .................................... 11
Z – Modem Reset ................................................. 11
AT Commands Definition ........................................... 4
Attention Code AT ...................................................... 8
Autoanswer S0 ......................................................... 26
B
Backspace Character Setting S5 ............................. 26
Blacklisting %B ......................................................... 14
Break Control \K ....................................................... 13
Busy-Out Timer at End of Call *DW ......................... 25
C
Call Waiting Enable +PCW= .................................... 17
Callback Attempts #CBA .......................................... 22
Callback Delay #CBD ............................................... 22
Callback Enable/Disable #CBS ................................ 23
Callback Failed Attempts Display #CBF? ................. 22
Callback Failed Attempts Reset #CBFR .................. 22
Callback Parity #CBP ............................................... 22
Callback Security commands
#CBA – Callback Attempts ................................... 22
#CBD – Callback delay ......................................... 22
#CBF? – Callback Failed Attempts Display .......... 22
#CBFR – Resetting Failed Attempts ..................... 22
#CBI – Local Inactivity Timer ................................ 22
#CBN= – Store Callback Password ...................... 22
Comentarios a estos manuales