Chapter 10 – V24-V25 Commands
Multi-Tech Systems, Inc. CDMA AT Commands Reference Guide (PN S000294K) 58
Chapter 10V.24-V.25
Commands
Refer to ITU-T Recommendation V.25 specifications if you desire more details about the following commands.
Fixed DTE Rate +IPR
Description: This command is used to specify the baud rate for the module DATA port. The factory default value is
115200. When autobaud is specified (AT+IPR=0), the module sets the DATA port operating baud rate to the
detected DTE baud rate. The AT&F command restores the baud rate value that was active when the last
AT&W command was used.
Note: The use of baud rates below 9600 may affect the operability of some module software features; e.g.,
TCP App.
Syntax: Command syntax: AT+IPR
Command Possible Responses
AT+IPR?
Note: Read syntax.
+IPR: 9600
OK
Note: Current rate is 9600 bps
AT+IPR=?
Note: List of supported <rate> values,[(list of
fixed-only <rate> values)]
+IPR: (0,1200,2400,4800,9600,19200), (45,50,75,
110,150,300,600,38400,57600,115200,230400)
OK Note: Possible value (
*)
AT+IPR=38400
Note: Disable autobaud and set rate to 38400 bps
OK
AT+IPR=0 Note: Enable autobaud OK
(*) The first list of values are the baud rates that are detectable by the module autobaud feature. The second
list of values are the module DATA port supported baud rates
.
DTE-DCE Character Framing +ICF
Description: This command is used to specify the UART start-stop (asynchronous) character framing for the module
DATA port. The factory default value is 3,3. The AT&F command restores the value that was active when
the last AT&W command was used.
Values: <format>
0 Autodetect (Not supported)
1 8 Data 2 Stop (Not supported)
2 8 Data 1 Parity 1 Stop (Not supported)
3 8 Data 1 Stop (Supported)
4 7 Data 2 Stop (Not Supported)
5 7 Data 1 Parity 1 Stop (Not Supported)
6 7 Data 1 Stop (Not Supported)
<parity>
0 Odd (Supported)
1 Even (Supported)
2 Mark (Supported)
3 None (Supported)
Note: The supported format values are software release specific. Use the +ICF=? command to display the valid
format values for the software release in use.
Syntax: Command syntax: AT+ICF= <format>, <parity>
Command Possible Responses
AT+ICF=3,3
Note: Set values.
OK
Note: New values set
AT+ICF?
Note: Display current settings.
+ICF: 3,3
OK
Note: Current values
AT+ICF=?
Note: Display valid parameter ranges.
+ICF: (3-5),(0-3)
OK
Note: Possible values
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 196 197

Comentarios a estos manuales

Sin comentarios

Sylvania 7" Dual Screen Portable DVD SDVD8727 manuales

Manuales del propietario y guías del usuario para Reproductores de dvd Sylvania 7" Dual Screen Portable DVD SDVD8727.
Ofrecemos manuales en pdf Sylvania 7" Dual Screen Portable DVD SDVD8727 para descargar gratis por tipos de documentos:






Más productos y manuales para Reproductores de dvd Sylvania

Modelos Tipo de documento
Ninguno