Multitech ISI3334/4 Especificaciones Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 71
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
ISI3334/4 Hardware/Driver Installation Manual
30
2.3 S-Registers
Certain Command Mode configurations are stored in memory
registers called, S-Registers. The
S
command is used to assign a
value to, and to read the current value of an S-Register. To assign a
value to an S-Register, enter the letter
S
,
followed by the S-Register
number and an equals sign (
=
), and then a decimal response to the
message
“ENTER THE NEW VALUE IN DECIMAL FORMAT”.
To
read an S-Register value, enter the letter
S
followed by the S-
Register number and a question mark (
?
), then hit RETURN. To
verify that the S-Register value was entered correctly, enter for
example,
ATS8?
and hit RETURN. You should receive a response
of the assigned value given to that S-Register.
S0
Number of Rings Until Modem Answers
Unit: 1 ring
Range: 0-255
Default: 0
Description: Sets the number of rings before the modem
answers.
S1
Rings Which Have Occurred
Unit: 1 ring
Range: 0-255
Default: 0
Description: Counts the number of rings that have
occurred.
S2
Escape Code Character
Unit: ASCII Character
Range: 0-127
Default: 43 (
+ sign
)
Description: Defines the escape code character.
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 70 71

Comentarios a estos manuales

Sin comentarios