Chapter4ConfiguringYourMultiVOIP
MultiVOIP®Voice/FaxoverIPGateways 63
SIPServerPredefinedEnd
p
ointsParameterDefinitions
FieldName Values Descri
p
tion
EndpointName name
IdentifierforgatewaywithinSIPVOIPsystem.Maximumlengthis33
characters.
Password password ThispasswordisforauthenticationofgatewaytoSIPserver.
Registration
Type
Static,
Dynamic
Staticregistrationsarefixedandthecontactinformationforthemis
configuredbytheuserandnotsubjecttoremovalfromtheregistration
listduetotimeouts.
Dynamicregistrationsareregisteredfromanexternalendpointwith
thecontactinformation.Dynamicentriesmustreregisterbeforethe
re
registrationintervalexpireselsetheyareremovedfromthelist.
Endpointsremovedfromthislistcanneithermakenorreceivecalls.
ReRegistration
Interval
integer
values;in
seconds;
defaultis
3600
ThetimeafterwhichtheMultiVOIPUserAgentClientissupposedto
registerwiththeproxyserver.
Expirationoftheregistrationintervalmeansthatthegatewayhaslost
contactwiththemainSIPserverandth attheMVPSSunitentersits
‘survivability’mode.Insurvivabilitymode,theMVPSSunitcompletes
callsactingasabackuptothemainSIPserver.Normally, however,the
MVPSSinitiatesreregistrationwithsomesmallmarginoftimebefore
theintervallapses.
ContactInformation
Address n.n.n.n TheIPaddres satwhichthisendpointcanbereached.
Port
0
64000
DigitaltimeslotonwhichSIPcallsaremade.Defaultis5060
ReRegistrationTime See“ReRegistrationInterval”entryabove.