Vista de pagina 45
sigmadue - IEC 61131-3 Function Block Library
38
Reference Table
P_IN 15.0
COMP_TYPE
0 = no compensation,
1 = temperature compensation only,
2 = pressure compensation only,
3 = both temperature and pressure compensation
T_REF 25.0
P_REF 30.0
P_ABS 1.013
Q_HIGH_LIM 100.0
Q_LOW_LIM 0.0
Output Description
ERR_CODE.0 Compensation type selection not valid
ERR_CODE.1 Actual Temperature value underrange (to avoid division by zero)
ERR_CODE.2 Actual flow value out of range
ERR_CODE.3 Reference and Absolute Pressure values equal to 0
Input Default Value