Multitech MT9234ZBAUSBCDC Guía de usuario Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 66
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
Chapter 1 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. AT Commands for the MultiModem & SocketModem MT9234 Series (S000434H) 34
+VDR Distinctive Ring Report
Description: Enables reporting of ring cadence information to the DTE and specifies the minimum
ring cadence that will be reported.
The report format is one line per silence period and one line per ring period. The
length of the silence period is in the form DROF=number in units of 100
ms<CR><LF>, and the length of the ring is in the form DRON=number in units of 100
ms<CR> <LF>. The modem may produce a Ring event code after the DRON
message if enabled by the y parameter. The y parameter must be set to a value
equal to or smaller than the expected ring cadence.
Syntax: AT+VDR=<value x>, <value y>
Values: x = 0, 1 Distinctive Ring report control. Default = 0.
y = 0–255 Minimum ring interval in 100 ms units. Default = 0.
+VDR=0, N/A Disables Distinctive Ring cadence reporting.
+VDR=1, 0 Enables Distinctive Ring cadence reporting. Other call progress
result codes (including RING) are reported as normal.
+VDR=1, >0 Enables Distinctive Ring cadence reporting. The RING result code is
reported after the falling edge of the ring pulse (i.e., after the DRON
report).
Reports: +VDR=? Displays the allowed values.
+VDR? Displays the current value.
#P Set 11-bit Parity
Description: Sets 11-bit parity.
Note: This command does not work with parallel, USB, PCI, PCIe.
Syntax: AT#P<value>
Values: 0 No parity.
1 Odd parity.
2 Even parity.
Default: 2
#S Enter Setup Password
Description: Verifies the Callback Security Password and allows the user to modify the Callback
Security settings.
Note: This command does not work with parallel, USB, PCI, PCIe.
Syntax: AT#S<password>
Values: password (1–8 characters, case sensitive)
Default Password: MTSMODEM
Response: OK if password is correct
ERROR if password is incorrect
#S= Store Setup Password
Description: Stores a new remote configuration setup or Callback Security password, depending
upon the model.
Note: This command does not work with parallel, USB, PCI, PCIe.
Syntax: AT#S=x
Values: x stands for password (1–8 characters, case sensitive)
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 65 66

Comentarios a estos manuales

Sin comentarios