Chapter 2 - Installation
FR111A
Setting Up Your MultiFRAD
If V.35 electrical interface signaling is required on the data port but a PC with EIA-232D signaling is
being used to configure the MultiFRAD, the unit has to be configured before you change to V.35
signaling. You need to set the DIP-switches, make the proper cable connections, configure the unit,
and then change to V.35 signaling on the data port.
1. Ensure that the DIP switch settings on the side of the unit are set for a command mode of
operation (i.e., Switch 1 is DOWN, Switches 2, 3 and 4 are UP).
O
n
e
-
P
o
r
t
F
r
a
m
e
R
e
l
a
y
A
c
c
e
s
s
D
e
v
i
c
e
w
i
th
5
6
K
D
S
U
T
D
R
D
D
S
U
N
S
O
O
S
C
D
D
S
U
DIP Switches
Figure 2-2. Data/Command Switch
Switch Mode Position Description
1 Cmd/Data UP* Data
DOWN Command
2 Clocking UP* DDS
DOWN Internal
3 Loopback UP* Normal
DOWN Loopback
4 DSU UP FRAD
DOWN* DSU
5 Force RTS UP Follows CTS
DOWN* Forced active
6 - 8 Not Used
* Factory default setting
2. Connect the external power transformer to the MultiFRAD and plug it into a live AC outlet. The
MultiFRAD does not have a power switch. When power is applied to the unit, it takes about 10
seconds for it to power-up.
Power Connection
RS-232 Cable
Connection
Power
Trunk
Data
RJ-48 Connection
Figure 2-3. Cable Connections