Multitech MMCModem GPRS (MTMMC-G) Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
Chapter 4 – Data Exchange for Protocol Services
Multi-Tech Systems, Inc. IP Connectivity AT Commands for GPRS-F4 Wireless Modems (PN S000437C) 23
Chapter 4 – Data Exchange for Protocol
Services
The section deals with the data exchange for the services over TCP/IP. All the commands required for the
data exchange through different services are mentioned in succeeding pages.
File Exchange +WIPFILE
Description: The +WIPFILE command define the “file system” services that allow sending a block
of data through standard TCP/IP protocols. This command is for file
transfer/reception.
Notes:
The SIM card must be inserted in order to use this command
The PIN 1/ CHV 1 code must be entered in order to use this command.
The PIN 2/CHV 2 code does not have to be entered in order to use this
command.
The +WIND general indication command value from which +WIPCREATE
is allowed is 4. This value (4) indicates that the product is ready to process
AT commands (except phonebooks, AOC, SMS), but is still in emergency
mode. See Appendix A – GSM/GPRS +WIND AT Command.
Syntax: AT+WIPFILE=<protocol>,<index>,<mode>,<filename>
Read command: AT+WIPFILE? Displays the current values.
Test Command: AT+WIPFILE=? Displays available values.
Parameters/Defined Values:
<protocol>: protocol type
4 FTP
<idx>: channel identifier
<mode>: file transfer mode
1 File retrieval: Wireless CPU
®
switches to data mode and prints
the content of the file on UART. The end of the file is marked by
[ETX] character. After this has been sent, the UART switches
back to AT mode.
2 File transfer: This command switches the UART in data mode
and accepts a stream of data terminated by [ETX] character.
<filename>: specifies the name of the file to send or retrieve.
The maximum file length is limited to 128 characters. The actual
filename, including path name has to be used.
Parameter Storage: None
Possible Errors:
“+CMEE” AT error code Description
800 invalid option
803 operation not allowed in the current WIP stack state
830 bad index
831 bad state
834 not implemented
836 memory allocation error
837 bad protocol
839 error during channel creation