Chapter 3.
DESTINATION
PLACEMENT
: Digital Part - Stripped wire to MDF.
For ACIO
Copy 0 Copy 1
Frame
TSU TSU
Slot
12 15
Connector
B B
TAB NO. RETAINED : For module 3
4 4
ASSEMBLY PROCEDURE : Wire wrapping tool
Soldering Iron (For jumper wire)
Ref. Fig. 3.3 and Tables 3-5.
For ACIO connection details refer
Table No.3-3.
* These parts are to be connected as shown in Fig. 3.3
Notes:
1. Wire wrap the pairs onto contact block pins of each module as per
wiring details given.
2. Snap the hood onto the contact block such that polarity tab(1) is
towards pin 1 as per wiring done.
3. The shields of the two digital trunk cables are joined together at MDF
end. Solder 32/0.2 square mm multistrand wire on to the shield (copper
braid) at the point shown and crimping terminal ring as shown.
4. The wire length shall be as shown in the figure.
5. Polarity tabs to be retained as given below module 1:2, module 2:3,
module 3:4.
6. Put 12.0mm PVC/Black silicon rubber sleeve of 50mm length at both
ends of L tied with cable ties.
7. The two digital trunk cables on each side (copy 0 and copy 1) are tied
together with cable ties.
Note:
All signal names are w.r.t. RBM side.