JUMPER SETTINGS FOR W9-W16 (BPU COPY 1)
BM NO. HORTING POSITION FUNCTION
2 W11, W12, W13, W14, W15 Copy id = 83
4 W12, W13, W14, W15 = 87
6 W11, W13, W14, W15 = 8B
8 W13, W14, W15 = 8F
10 W11, W12, W14, W15 3 = 93
12 W12, W14, W15 = 97
14 W11, W14, W15 = 9B
16 W14, W15 = 9F
18 W11, W12, W13, W15 = A3
20 W12, W13, W15 = A7
22 W11, W13, W15 = AB
24 W13, W15 = AF
26 W11, W12, W15 = B3
28 W12, W15 = B7
30 W11, W15 = BB
32 W15 = BF
Note :
1. The mechanical jumpers have to be shorted as shown above.
2. The jumpers not mentioned to be left open.
4.4. EXTENDING IOP TERMINAL TO RSU SITE USING MODEMS
Two modems are required to extend IOP terminals to RSU site. One modem is
required at IOP end and other at RSU end. Modems can be configured for leased
line working or dial up working using AT commands and jumper settings. Modem
setup is shown in Fig. 4.1. To configure the modem, refer modem users
guide/operation manual.