4. Set serial baud rate and modem baud rate to 9600 bps
5. Disable DTR signal
Note :
1. For configuring modem using AT commands; power on modem, connect
terminal to modem, issue AT commands to achieve required
configuration. For exact commands, refer modem user guide/operation
manual.
2. Use jumper settings if any, to achieve above configuration
3. Typical AT commands for configuring multi-tech MT2834ZDX are
given in section 4.4.3, 4.4.4 for reference.
4.4.3. Procedure for Configuring Multitech (MT2834ZDX) for Dial Up
Working
For dial up working the following are the commands for configuring modem.
AT&F8&W0
AT$SB9600&W0
AT$MB9600&W0
AT&E3&W0
AT&D0&W0
ATS0=1&W0
Jumper settings lease/dial may be set to dial position modem. Set up may be
made as shown in Fig. 4.1.
4.4.4. Procedure for Configuring Multitech (MT2834ZDX) for Leased Line
Working
Step 1:
Configure one modem as originate modem as follows :
Connect terminal to modem, set terminal speed to 9600, power on modem. On
typing 'AT', the modem responds as saying "OK".
AT&F8&W0 (Store default settings and save)
AT$SB9600&W0 (Serial baud rate set to 9600 and save)
AT$MB9600&W0 (Modem baud rate set to 9600 and save)
AT&E3&W0 (Disable flow control and save)