SIESPACE Reported Faults
106 Sign: Power Failed
The sign has detected that the
mains power supply has failed to
the sign. Unless the power has
been restored subsequently the
sign will have been blanked. Not
all signs have a battery backup,
enabling them to inform the
SIESPACE instation of power
failure.
107 Sign: LED Failure
The sign has detected that one or
more LED characters have failed.
An indication of the number of
failed characters is usually
available. Not all signs are able to
detect this failure condition.
108 Sign: Lantern Failure
The sign has detected that the
amber lanterns have failed. Not
all signs are able to detect this
failure condition.
109 Sign: Tube Failure
The sign has detected that the
illuminating fluorescent tubes
have failed, where fitted. Not all
signs are able to detect this
failure condition.
110 Sign: Processor Fault
The sign has detected an internal
processing fault.
111
Sign: LED Communication
Failure
The sign has detected that
communications between the sign
processor and the characters has
failed. Not all signs are able to
detect this failure condition.
112 Sign: Failed to Set Message
The sign was unable to set the
requested message, either due to
a fault at the sign, or because it
contained illegal characters, or
the wrong number of characters.
113 Sign: Invalid Legend Requested As Error Code 101
Car Park Faults
Error Code Fault Name Meaning of Fault Maintenance Notes
file:///A|/html/reported_faults.htm (2 of 4) [27/06/2001 20:46:16]