Car Park Configuration - Thresholds
Car Park Configuration - Thresholds
There are four thresholds which define when the car park changes state. When numbers are increasing, the state is
defined as SPACES until the ALMOST FULL increasing threshold is reached, this state is maintained until the FULL
threshold is reached. When numbers are decreasing from FULL the state changes to ALMOST FULL when the
ALMOST FULL decreasing threshold is reached, then to SPACES when the decreasing SPACES threshold is
reached.
The FULL threshold can be set to any number up to the figure specified as CAPACITY, but it is advisable for it to be
lower to introduce hysteresis into the system so it does not hunt between two states. The ALMOST FULL increasing
threshold must be lower than the ALMOST FULL decreasing threshold also to introduce hysteresis. For obvious
reasons, the decreasing SPACES threshold must be the lowest of the four values.
You can select to display the threshold values as a percentage of the capacity, or as an absolute occupancy value.
This is done with the "Display Thresholds as %" checkbox.
The Overflow Threshold defines a percentage or absolute value which the car park can overflow by before a fault is
raised. This can be used to cope with car parks which have a high degree of internal circulating traffic.
The
Advanced button allows you to specify values which are only applicable to the Siemens Car Park Outstation. It
is capable of reporting car park occupancies based on exception, rather than by continuous polling.
Back to Basic Information
On to State Change Delays