Vista de pagina 83
MultiVOIP Gatekeeper User Guide 85
Appendix D - Regulatory Information
)mm(ecnaraelC)mm(egapeerC
detareneGrodesUegatloV
sdraCrehtOrotsoHyb
0.2)8.3(4.2cdVrosmV05otpU
6.2)8.4(0.3cdVrosmV521otpU
0.4)0.8(0.5cdVrosmV052otpU
0.4)0.01(4.6cdVrosmV003otpU
Power Supply Unit
or other source of
excessive voltage
Communication Module
Carrier Card Expansion Card
X
X
Example Diagram Showing Creepage
and Clearance Distances
Y
Y
Fig. B-1. Example Diagram Showing Creepage and Clearance Distances
Except at the edge connector which plugs into the host's expansion slot, clearance distance (Xmm) and
creepage distance (Ymm) as given in the table above, must be maintained between the communication
card and any assemblies which use or generate hazardous voltage.
This apparatus has been approved for the use of the following facilities:
Auto-calling
Loop disconnect and MF dialing
Phone number storage and retrieval by a predetermined code
Operation in the absence of proceed indication
Automatic storage of last number dialed
Tone detection-busy
Auto clear from the originating end
DTR dialing
Modem
PBX timed break register recall
European Low Voltage Directive
When correctly installed and maintained, the modem will present no hazard to the user. When correctly
installed, the modem will be connected to the PSTN or a PW and to a Data Terminal Equipment (DTE)
whose modem connections comply with CCITT recommendation V28. The DTE connections are therefore
taken to be safe voltages (less than ± 30 volts).