AUDIO COMMANDS
211 AT Commands for EV-DO-EV3 Modems
<agc_exp_thres> Expansion threshold. This is the input energy threshold under which
expansion is applied. This parameter must be less than agc_compr_thres.
Meaningful range is 0x0 to 0x2580. Write 0 to disable the expander.
Value(agc_exp_thres) = 128
(X+75) : X range is -75 to 0 dBm0mu.
<agc_exp_slope> Expansion slope. This is the expander gain slope when expansion is applied.
Meaningful range is 0xFF01 to 0xFFF6.
Value(agc_exp_slope) = 256 * X : X range is -0.04 to -0.996.
<agc_compr_thres> Compression threshold. This is the input energy threshold above which
compression is applied. Meaningful range is 0x0 to 0x2580. This parameter
must be greater than agc_exp_thres.
Value(agc_compr_thres) = 128
(X+75) : X range is -75 to 0 dBm0mu.
<agc_compr_slope> Compression slope. This is the slope of the compressor gain when
compression is applied. Meaningful range is 0x8000 to 0xFFFF.
Value(agc_compr_sloop) = 65536 * X : X range is 0.50001 to 0.99999.
Notes
These values are automatically saved in non-volatile memory.
Examples
AT#SHSAGCTX?
#SHSAGCTX: 2000,0,F00,FF29,2080,E666
OK
AT#SHSAGCTX=?
#SHSAGCTX: (2000-FFFF),(0,FFFF),(0-2580),(FF01-FFF6),(0-2580),(8000-FFFF)
OK
RX AGC Enable #SRXAGC
Set command sets the RX AGC enabling.
Read command returns the current RX AGC, in the format:
#SRXAGC: <mode>
Test command reports the supported range of values for <mode>.
Syntax
Command Command type
AT#SRXAGC=<mode> Set
AT#SRXAGC? Read
AT#SRXAGC=? Test
Parameters and Values
<mode>
0 Disables RX AGC. Default: 0.
1 Enables RX AGC.
Comentarios a estos manuales