V.250 AT COMMANDS
AT Commands for EV-DO-EV3 Modems
46
Tips for Selecting and Setting S-Parameters
ATSn<CR> selects n as current parameter number. If the value of n is in the range (0, 2, 3, 4, 5, 7, 10, 12, 25),
this command establishes Sn as last selected parameter. Every value out of this range and less than 256 can
be used but has no meaning and is maintained only for backward compatibility with landline modems.
AT=<value><CR> or ATS=<value><CR> set the contents of the selected S-parameter. For Example
ATS7=10<CR> Establishes S7 as last selected parameter and sets the S7 contents to 10.
AT=40<CR> Sets the content of S7 to 40.
ATS=15<CR> Sets the content of S7 to 15.
AT? <CR> Returns the S7 current value.
Notes
Reference: V.25ter and RC56D/RC336D.
Number of Rings to Auto Answer S0
Set command sets the number of rings required before device automatically answers an incoming call.
Read command returns the current value of S0 parameter.
Syntax
Command Command type
ATS0=[<n>] Set
ATS0? Read
Parameters and Values
<n> Number of rings.
0 Auto answer disabled. Default: 0.
1-255 Number of rings required before automatic answer.
Notes
Does not apply to non-voice models when receiving an inbound voice call.
Reference: V.25ter.
Ring Counter S1
S1 is incremented each time the device detects the ring signal of an incoming call. S1 is cleared as soon as no ring
occurs.
Read command returns the value of this parameter.
Syntax
Command Command type
ATS1
ATS1? Read
Notes
The form ATS1 has no effect.