V.250 AT COMMANDS
31 AT Commands for EV-DO-EV3 Modems
Parameters and Values
<n>
0-1 Profile number. The wireless module can store 2 full configurations. See &W.
Notes
Different from command Z<n>, which loads the desired profile just once; the profile chosen through
command &P loads on every startup.
If parameter is omitted, the command has the same behavior as AT&P0.
Store Current Configuration &W
Execute command stores the complete configuration of the device in profile <n>.
Syntax
Command Command type
AT&W[<n>] Execute
Parameters and Values
<n>
0-1 Profile.
Notes
If parameter is omitted, the command behaves the same as AT&W0.
Store Telephone Number &Z
Execute command stores the telephone number <nr> in the record <n>. The records cannot be overwritten. You
must clear them before rewriting.
Syntax
Command Command type
AT&Z<n>=<nr> Execute
Parameters and Values
<n> Phonebook record, 0-9.
<nr> String type, telephone number.
Notes
The wireless module has built-in, non-volatile memory where you can store 10 telephone numbers, each
with a maximum 24 digits.
To delete the record <n>, issue the command AT&Z<n>=<CR>.
Use the command &N to view the records in the module memory
To dial the telephone number stored in the record use the command ATDS=<n>.
Example
Store the number to index 0:
AT&Z0=5554443333