Appendixes
79
MTPSR1-202ST
ends, normal DTR monitoring resumes (assuming DTR is being monitored -- &D1, &D2, or &D3). If
DTR drops during the delay period, the data call will not be disconnected.
S-Register:
S32
Function: Escape Sequence Timeout
Unit: 100 ms
Range: 0–255
Default: 20
Description:
S32
sets the time allowed in an escape sequence from the receipt of the
A
in
AT
to
the receipt of the carriage return. If the
S32
time interval expires before you press ENTER, the es-
cape sequence ends. The default time is 2 seconds.
S-Register:
S50
Function: Caller Line ID “CLI”
Unit: Decimal ASCII code
Range: 0 or 1
Default: 1(enabled)
Description:
S50
sets whether the mechanism for identifying the two endpoints of a connection is
enabled or disabled. Since RING messages only appear for ISDN data calls, the CLI feature does
not define a means of conveying Calling Party information to the terminal for ISDN voice calls. The
CLI information is only included with the first RING message for a given incoming call, and appears
as follows:
RING
FM: 5552000 TO: 5551000
If the Calling Party Number information is not included in the incoming SETUP message, the RING
message appears as follows:
RING
TO: 5551000
If the Called Party Number information is not included in the incoming SETUP message, the RING
message will appear as follows:
RING
FM: 5552000
If neither the Called Party Number, nor the Calling Party Number is included in the incoming SETUP
message, the RING message will contain no additional information.
S-Register:
S52
Function: Auto-Protocol Detection
Unit: Decimal ASCII code
Range: 0 or 1
Default: 0
Description:
S52
sets whether the mechanism for identifying V.110, V.120, X.75, MLPPP, or
SoftBond operation is enabled or disabled. This is applicable for an ISDN data call; and once deter-
mined by the ProxyServer the protocol used by means of the information conveyed by the SETUP
message, then the indicated protocol is activated. The default setting is 0, which disables the Auto-
Protocol Detection function.
S-Register:
S53
Function: Maximum Frame Size (X.75)
Unit: Decimal ASCII code
S-Register:
S54
Function: Force 56 Kbps B-Channel Data Rate
Unit: Decimal ASCII code
Range: 56 (Kbps), or 64 (Kbps)
Default:64 (Kbps)