Chapter 2 – AT Commands
Multi-Tech Systems, Inc. SocketWireless Bluetooth AT Commands (S000360H) 41
SSNIFF Enable Auto Sniff
This command stores sniff parameters permanently in flash and auto starts sniff mode after a
connection is established.
Warning – Sniff seems to intermittently work using this command. Approximately 1 in 5
connections will not automatically go into sniff mode. Use ATSNIFF to guarantee that sniff mode
is started correctly.
Format: ATSSNIFF,<Max Interval>,<Min Interval>,<Attempt>,<Timeout>
Parameters:
• Max Interval: Integer Value
Time [ms] = Max Interval * 0.625ms
• Min Interval: Integer Value
Time [ms] = Min Interval * 0.625ms
• Attempt: Integer Value
Time [ms] = Attempt * 0.625ms
• Timeout: Integer Value
Time [ms] = Timeout * 0.625ms
EXAMPLE:
TYPE: ATSSNIFF,1600,160,10,160<cr>
REPLY: <cr_lf>OK<cr_lf>
OR
<cr_lf>ERROR<cr_lf>
Read Using: ATSI,17
CSNIFF Clear Sniff
This command clears sniff parameters.
Format: ATCSNIFF
Example:
Type: ATCSNIFF<cr>
Reply: <cr_lf>OK<cr_lf>
OR
<cr_lf>ERROR<cr_lf>
XSNIFF Exit Sniff Mode
This command tells the module to exit and stop "sniffing" RF signals.
Format: ATXSNIFF
Example:
TYPE: ATXSNIFF<cr>
REPLY: <cr_lf>OK<cr_lf>
OR
<cr_lf>NO CARRIER<cr_lf>