Chapter 2 – AT Commands
Multi-Tech Systems, Inc. SocketWireless Bluetooth AT Commands (S000360H) 42
PARK Enable Park
This command manually enables park mode for the device connected in time slots.
Format: ATPARK,<MAX Interval>,<MIN Interval>
Parameters:
Max Interval: Integer Value
Time [ms] = Max Interval * 0.625ms
Min Interval: Integer Value
Time [ms] = Min Interval * 0.625ms
EXAMPLE:
TYPE: ATPARK,1000,11<cr>
REPLY: <cr_lf>OK<cr_lf>
OR
<cr_lf>NO CARRIER<cr_lf>
Notes:
Allow 7 seconds for the slave to drop its average current draw from 45mA to 3mA and go
into PARK. Any UART traffic will cause the Slave radio go back to full operation within
5msec of the first character for 7 seconds before going back into PARK mode without
subsequent data. The Slave will remain connected to the Master because the
BlueRadios Module only supports one connection.
Both units are required to support park. Park request is sent from both Master and Slave
to go into affect only during an active Bluetooth connection. The order does not matter.
XPARK Exit Park
This command tells the device to exit the park mode.
Format: ATXPARK
EXAMPLE:
TYPE: ATXPARK<cr>
REPLY: <cr_lf>OK<cr_lf>
OR
<cr_lf>NO CARRIER<cr_lf>
Note: Unit will immediately exit park.
RSSI and Link Quality Commands
Golden Receive Power Range
The lower threshold level of the Golden Receive Power Range corresponds to a receive power between -56
dBm and 6 dB above the actual sensitivity of the receiver. The upper threshold level is 20 dB above the lower
threshold level to an accuracy of +/-6 dB.
RSSI Get RSSI Value
This command is used to obtain the RSSI value for an open connection on channel 0. This is a
parameter associated with the ACL connection to a peer device.
Format: ATRSSI
Return Parameters: <RSSI Value>
RSSI Value is in hex, typically from -10 to +31 in integer dB value.
EXAMPLE:
TYPE: ATRSSI<cr>
REPLY: <cr_lf>OK<cr_lf>
<cr_lf>+00<cr_lf>
OR
<cr_lf>ERROR<cr_lf>