Chapter 3 – Factory Default Settings
Multi-Tech Systems, Inc. SocketWireless Bluetooth AT Commands (S000360H) 58
Chapter 3 – Factory Default Settings
Note: Appling 3.3Vdc on PIO(4) for >2 sec. during initial power up will revert all user definable settings to the
factory defaults shown below. Note: This does not apply to the MultiConnect Adapter.
The other option for resetting factory defaults is to use the software command ATFRST. The only exception
for these two options is the name of the device (friendly name) and the PIN – these will not reset if you had
changed them already. Allow approximately 5 seconds for the device to reconfigure.
• Bypass Hardware Factory Reset = Enabled
• Escape Character = ‘+’
• Max Connection Number = 1
• Radio Name = “SocketWireless”
• Country Code = North America and Europe
• Boot Mode = Virtual Machine (VM) Mode
• Service Name = “COM0” (Ch0), “COM1” (Ch1), “COM2” (Ch2), “COM3” (Ch3)
• PIN = “default”
• COD = 00000000
• UART Setting = 9600 Baud, 8 Data Bits, No Parity, 1 Stop Bit (8,N,1)
• Hardware flow control RTS/CTS = Enabled
• Page Scan Interval = 1024 (640ms)
• Page Scan Window = 512 (320ms)
• Inquiry Scan Interval = 1024 (640ms)
• Inquiry Scan Window = 512 (320ms)
• PIO Directions (Point to Point) = 6-In, 7-In
• PIO Directions (Multipoint) = 6-Out, 7-Out
• Response Type = Long Response
• Security = Disabled (If the security flag is enabled a factory reset of parameters does not disable security)
• Security Level = Link Level, if security flag is enabled services are provided only with PIN exchange.
• Automatic SCO Connect = Disabled
• Minor Filter = Disabled
• Default Boot Mode = Slave
• Radio Status = 1,0 (Slave Disconnected)
• Default Comm Mode = Data
• Unconnected UART Mode = Allow Data to Pass While Unconnected
• Bluetooth Service Profile = Serial Port Profile (SPP)
• Lock User Settings = Disabled
• PIO(5) LED Rate = 1000ms
• Inquiry Timeout = 16s
• Master Connect Request Timeout = 40s
• PIN Lock Mode = ATOP Disable
• Deep Sleep Mode = Never Go Into Deep Sleep
• Pairing Timeout = 30 seconds
• Class1 Radio Max Transmit Power = 15dbm. Class2 module will still have a max of 4dbm output
performance even though you can set it to 15.
• Link Supervisory Timeout = ~4s
Miscellaneous Note: