Chapter 3 – Factory Default Settings
Multi-Tech Systems, Inc. SocketWireless Bluetooth AT Commands (S000360H) 58
Chapter 3 – Factory Default Settings
Note: Appling 3.3Vdc on PIO(4) for >2 sec. during initial power up will revert all user definable settings to the
factory defaults shown below. Note: This does not apply to the MultiConnect Adapter.
The other option for resetting factory defaults is to use the software command ATFRST. The only exception
for these two options is the name of the device (friendly name) and the PIN – these will not reset if you had
changed them already. Allow approximately 5 seconds for the device to reconfigure.
Bypass Hardware Factory Reset = Enabled
Escape Character = ‘+’
Max Connection Number = 1
Radio Name = “SocketWireless”
Country Code = North America and Europe
Boot Mode = Virtual Machine (VM) Mode
Service Name = “COM0” (Ch0), “COM1” (Ch1), “COM2” (Ch2), “COM3” (Ch3)
PIN = “default”
COD = 00000000
UART Setting = 9600 Baud, 8 Data Bits, No Parity, 1 Stop Bit (8,N,1)
Hardware flow control RTS/CTS = Enabled
Page Scan Interval = 1024 (640ms)
Page Scan Window = 512 (320ms)
Inquiry Scan Interval = 1024 (640ms)
Inquiry Scan Window = 512 (320ms)
PIO Directions (Point to Point) = 6-In, 7-In
PIO Directions (Multipoint) = 6-Out, 7-Out
Response Type = Long Response
Security = Disabled (If the security flag is enabled a factory reset of parameters does not disable security)
Security Level = Link Level, if security flag is enabled services are provided only with PIN exchange.
Automatic SCO Connect = Disabled
Minor Filter = Disabled
Default Boot Mode = Slave
Radio Status = 1,0 (Slave Disconnected)
Default Comm Mode = Data
Unconnected UART Mode = Allow Data to Pass While Unconnected
Bluetooth Service Profile = Serial Port Profile (SPP)
Lock User Settings = Disabled
PIO(5) LED Rate = 1000ms
Inquiry Timeout = 16s
Master Connect Request Timeout = 40s
PIN Lock Mode = ATOP Disable
Deep Sleep Mode = Never Go Into Deep Sleep
Pairing Timeout = 30 seconds
Class1 Radio Max Transmit Power = 15dbm. Class2 module will still have a max of 4dbm output
performance even though you can set it to 15.
Link Supervisory Timeout = ~4s
Miscellaneous Note:
Retries for over-the-air RF-guaranteed data packet is set for indefinite.