Chapter 1 – General AT Commands
14 Universal IP AT Commands Reference Guide
Examples:
0-4; 3 if the input is left blank
0-4; 3 if the input is left blank
+IFC – Set Flow Control
Description: Turns flow control on and off.
Syntax: AT+IFC=<flow control value>
Values: 0,0 Flow Control Off
2,2 Hardware Flow Control On
Default: 2,2 Hardware Flow Control On
+IPR – Set Serial Speed
Description: Sets the serial speed.
Syntax: AT+IPR=<serial speed value>
Values: 300 to 921600
Display: AT+IPR? Displays the current serial speed.
AT+IPR=? Displays a list of all possible values (serial speeds).
Default: For All Products: 115200
#AUTORESET - Reset the Processor at a Given Time
Description: Set an amount of time when the modem will reset after no input has been detected on the
serial port.
This command is not supported on the SocketEthernet IP (MT100SEM-IP).
Syntax: AT#AUTORESET=<time in minutes>
AT#AUTORESET? or AT#VALL
Values: 0-65535 the time in minutes
From 1 to 5 numeric digits (0 to 9).
Default: 0
#DELFLASH – Erase Flash Memory Parameter Values
Description: This command erases the contents of the flash memory and loads with defaults values.
Syntax: AT#DELFLASH
Values: No parameter values.