Part 1 AT Commands for All Universal IP Devices
Universal IP AT Commands Reference Guide 39
#TCPINACTIVITYTIMER TCP Client Inactivity Timeout Value
Description: This parameter determines the inactivity time in seconds as to when a socket connection will
automatically disconnect.
This command is for all devices except the SocketWireless Wi-Fi (MT810SWM-IP)
Note: Data transmission from either the remote or local side will reset the internal timer to
the #TCPINACTIVITYTIMER value
Syntax: AT#TCPINACTIVITYTIMER=<parameter1>, <parameter2>
Values: parameter 1
1 TCP profile 1
2 TCP profile 2
parameter 2
0-65535 the time in seconds of inactivity before a socket will automatically disconnect. A
setting of 0 will disable the function.
Responses: \r\n#TCPINACTIVITYTIMER: VALUE1,VALUE2\r\n
\r\nOK\r\n
\r\nERROR\r\n
Examples: send: AT#TCPINACTIVITYTIMER=1,100\r
reply: \r\nOK\r\n
send: AT#TCPINACTIVITYTIMER=1\r
reply: \r\n#TCPINACTIVITYTIMER: 1,100\r\n
reply: \r\nOK\r\n
send: AT#TCPINACTIVITYTIMER=2,300\r
reply: \r\nOK\r\n
send: AT#TCPINACTIVITYTIMER=2\r
reply: \r\n#TCPINACTIVITYTIMER: 2,300\r\n
reply: \r\nOK\r\n