IP Commands – Setup
Command Syntax set ip udp udp-inactivity-timeout <t secs>
Description
If the UDP session is inactive for ‘t’ secs, the connection is terminated.
This functionality is applicable only if “set udp inactivity” is enabled. (Refer to the ’set
ip udp inactivity’ command).
Default Value
300
Success
OK
Error 1. Too few arguments
“Usage: set ip udp udp-inactivity-timeout <t secs>
Type ‘set ip udp udp-inactivity-timeout ?’ for more information”
2. Multiple matches
udp-inactivity
udp-inactivity-timeout
3. Invalid argument
“error: ‘t secs range : 1 – 18000
Type ‘set ip udp udp-inactivity-timeout ?’ for more information”
Command Syntax set ip udp udp-terminate-monitor <enable/disable>
Description
‘‘Monitor’’ flag enables/disables scanning of terminate sequence by the UDP server.
Default Value
Enabled
Success
OK
Error 1. Too few arguments
“Usage: set ip udp udp-terminate-monitor <enable/disable>
Type ‘set ip udp udp-terminate-monitor ?’ for more information”
2. Multiple matches
udp-terminate-monitor
udp-terminate-string
3. Invalid argument
Type ‘set ip udp udp-terminate-monitor ?’ for more information”
Command Syntax set ip udp udp-terminate-string <string>
Description
The UDP Server scans for this terminate sequence and terminates UDP auto-
dialout session.
By default, the UDP Server scans for “+++inet”.
Default Value
+++ inet
Success
OK
Error 1. Too few arguments
“Usage: set ip udp udp-terminate-string <string>
Type ‘set ip udp udp-terminate-string ?’ for more information”
2. Multiple matches
udp-terminate-monitor
udp-terminate-string
3. Invalid argument
Type ‘set ip udp udp-terminate-string ?’ for more information”