Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 30
Serial Commands – Setup
Command Syntax Set serial [s0/s1] connect-type <direct/modem>
Description
Sets the connect type of the serial port to direct/modem connect.
Modem port (s1) will always have connect-type as modem since it is a built-in modem
Default Value
Direct
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 connect-type <direct/modem>
Type ‘set serial s0/s1 connect-type ?’ for more information”
2. Invalid string
“error: Invalid string
Type ‘set serial s0/s1 connect-type ?’ for more information”
3. If “set serial s1 connect-type direct” is given
error: modem port s1 is a built-in modem interface and cannot be set to direct
Command Syntax set serial [s0/s1] connect-state <answering/dialing/both>
Description Sets the connect state of the serial port to answering/dialing/both state.
Default Value
Both
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 connect-state <answering/dialing/both>
Type ‘set serial s0/s1 connect-state ?’ for more information”
2. Invalid string
“error: Invalid string
Type ‘set serial s0/s1 connect-state ?’ for more information”
Command Syntax set serial [s0/s1] data-bits <7/8>
Description
Set the data-bits.
Default Value
8
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 data-bits <7/8>
Type ‘set serial s0/s1 data-bits ?’ for more information”
2. Invalid data-bit setting
“error: Data-bits range supported: [7/8]
Type ‘set serial s0/s1 data-bits ?’ for more information”
Command Syntax set serial s0 dialout-monitor <dtr/none>
Description When set to dtr, enables monitoring DTR on s0 and terminates the dialout (manual
or auto) session upon toggle of DTR from HIGH to LOW.
Default Value
None
Success
OK
Error 1. Too few arguments
Usage: set serial s0 dialout-monitor <dtr/none>
Type 'set serial s0 dialout-monitor ?' for more information.
ERROR
2. Invalid argument
Type ‘set serial s0 dialout-monitor ?’ for more information”
Command Syntax set serial s0 echo-command <enable/disable>
Description
Enables/disables the command echo during configuration from TTY or telnet client.
Default Value
Enable
Success
OK
Error 1. Too few arguments
Usage: set serial s0 echo-command <enable/disable>
Type 'set serial s0 echo-command ?' for more information.
ERROR
2. Invalid argument
Type ‘set serial s0 echo-command ?’ for more information”