Multitech MultiConnect Adapter Guía de usuario Pagina 81

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 154
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 80
Chapter 6 – Serial-to-Network Connectivity Using Serial Dial-in
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 81
Scenario 4 – Serial Tunneling Mode
The scenario shows how to setup serial-to-serial tunneling using two MTS2SA (Serial-to-Serial) adapters/device
servers, two external modems, and two phone lines. Assume both MTS2SAs are using factory default settings.
Serial Tunneling
Setup Serial Tunneling Feature
Setup MTS2SA Adapter/Device Server #1
Setup as Auto-Dialout (Wait & Answer Call)
Setup MTS2SA Adapter/Device Server #2
Setup as Auto-Dialout (Dialing & Making the
Call to MTS2SA #1)
# set ip telnet auto-dialout enable
# set serial auto-telnet enable
# set ip telnet raw enable
# set serial s0 raw-dialin enable
# set serial s0 raw-dialout enable
# set serial s1 connect-type modem
# set ppp ppp0 ipcp-mode client-or-lan
# set ppp ppp0 dialing-max-retries 3
# set ppp ppp0 dialing-retry-interval 10
# set ppp ppp0 idle-timeout 0
# set ppp ppp0 authentication enable
# set ppp ppp0 auth-type pap-chap
# set ppp ppp0 username test
# set ppp ppp0 password test
# set ppp ppp0 local-ip-addr 202.1.1.2 mask
255.255.255.0
# set ppp ppp0 remote-ip-addr 202.1.1.1 mask
255.255.255.0
# set serial s1 modem dialing-trig-mode command
# set login auto-dialout disable
# save
# set serial auto-telnet enable
# set ip telnet raw enable
# set serial s0 raw-dialin enable
# set serial s0 raw-dialout enable
# set serial s0 auto-dialin trig-mode dtr-char
# set serial s0 auto-dialin-ipadd 202.1.1.2
# set serial s0 auto-dialin-port 5000
# set serial s1 connect-type modem
# set serial s1 modem dial-number 5965
# set serial s1 modem hangup ""
# set ppp ppp0 ipcp-mode client-or-lan
# set ppp ppp0 dialing-max-retries 3
# set ppp ppp0 dialing-retry-interval 10
# set ppp ppp0 idle-timeout 0
# set ppp ppp0 authentication enable
# set ppp ppp0 auth-type pap-chap
# set ppp ppp0 username test
# set ppp ppp0 password test
# set ppp ppp0 local-ip-addr 202.1.1.1 mask
255.255.255.0
# set ppp ppp0 remote-ip-addr 202.1.1.2 mask
255.255.255.0
# set serial s1 modem dialing-trig-mode none
# set serial s0 auto-dialin enable
# save
You will have to change the dial number "set serial s1 modem dial-number 5965" to match up with the phone line that
is connected to adapter #1
In order to terminate the auto-dialin setup in Adapter #2, perform the following:
1. Make sure your firmware version is 1.08 or above. If you have 1.07 or below, you will have to reflash the
firwmare.
2. Power off and on. Then when you see the Ready message, you have 3 seconds to press Control+C. A login
prompt displays. If you do not see the login prompt, repeat this step.
Vista de pagina 80
1 2 ... 76 77 78 79 80 81 82 83 84 85 86 ... 153 154

Comentarios a estos manuales

Sin comentarios