Chapter 2 – Command Line Interface (CLI)
Command Line Interface and Application Examples for Multi-Tech Systems, Inc. IP Modules (S000368F) 20
Serial Commands – Setup
Serial Setup Commands
Command Syntax set serial auto-dialin <enable/disable>
Description
This command globally enables serial auto dial-in support.
Notes:
This feature provides a dial-in session to the serial device connected to s0
through the IP-enabled modem port (s1)
Also, dial-in can be done only after PPP is up and has acquired an IP address on
the modem's (s1) port.
Default Value
Disabled
Success
OK
Error 1. Too few arguments
“Usage: set serial auto-dialin <enable/disable>
Type ‘set serial auto-dialin ?’ for more information”
2. Invalid string
error: Invalid string
Type ‘set serial auto-dialin ?’ for more information
Command Syntax set serial <serial-interface> escape-monitor <enable/disable>
Description
Sets a ‘‘monitor’’ flag that enables/disables the scanning of escape sequence.
Default Value
Enable
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 escape-monitor <enable/disable>
Type ‘set serial s0/s1escape-monitor ?’ for more information”
2. Multiple matches
escape-monitor
escape-string
3. Invalid string
error: Invalid string
Type ‘set serial s0/s1 escape-monitor ?’ for more information”
Command Syntax set serial <serial-interface> escape-string <string>
Description
The Telnet client scans for this escape sequence and transfers the control to the
command parser.
By default, the Telnet client scans for “+++inet”.
Default Value
+++ inet<serial-interface>
Success
OK
Error 1. Too few arguments
“Usage: set serial s0/s1 escape-string <string>
Type ‘set serial s0/s1 escape-string ?’ for more information”
2. Multiple matches
escape-monitor
escape-string
Command Syntax hangup [serial interface]
Valid serial interface – Modem port s1
Description
When this command is issued, the established live link is brought down.
This command is only valid only for modem port (s1)
Default Value
-
Success If physical link is brought down, OK and
Physical link is successfully brought down messages are given
Error 1. Too few arguments
"Usage: hangup [s1]
Type 'hangup [s1] ?' for more information"
2. “error: Link could not be brought down”
message is given when link could not be brought down